The CopperTest 100 has been specifically designed for testing the 'last mile' copper at the end of Fibre to the Building installations (FTTB) or from within the building. Our small practical unit provides full copper test head functionality in an ultra-low cost package. It has been designed to eliminate the huge OpEx costs associated with fault detection in building wiring and identifying customer termination problems. The CopperTest 100 can be supplied as a stand alone Test Head or as an OEM module that can be built into an existing rack or product. A fully specified command set allows the user to incorporate the module control into existing customer management systems.
|
![]() |
Note: Specification is dependent on UTest model and can be mixed and matched to meet customer requirements
|
DC voltage testsRange: -300 to +300 voltsAccuarcy: ±5% Resolution: 1 volt Tests: B-leg/Earth A-leg/Earth B-leg/A-leg AC voltage tests Range: 0 to 300 volts RMS Resistance tests Range: 0Ω to 500KΩ Capacitance tests Range: 0μF to 2μ |
Alarms10 inputsMax voltage: 70V Isolation: 2500Vac (RMS) 2 Dry contact outputs: Mx Voltage: 220VDC, 250VAC Max Current: 2A Max Power: 60VA Indicator1 Green LED:Idle Flashing at 1Hz Busy: Falashing at 10Hz Lost COM: Constant on Hardware failure: Off Communication PortsRS485 port: 1 DimensionsSize (HxWxD): 11.5x115.0x161.7 millimetresSupply voltageDC supply: 12 volts Power ConsumptionNormal testing: 1.5WOperating environmentTemperature range: -40°C to 85°CReliabilityMTBF: 76.6 years (HRD5)Connections10-pin connector: power, comms, address96-pin connector: alarm inputs, alarm outputs, look in test pair and look out test pair |
U-Test 100 Features |
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
Commands:The CopperTest 100 comes with the following command set.
U-Test 100 Road MapPower Spectral Density tests including Crosstalk measurement. Detect Load Coils / RF Filters / BB Telephone Filters missing (TBA) Frequency Domain Reflectometry (FDR) for detailed line diagnostics |
Further information on Copper Test Heads and metallic test access units can be found at UTEL |